Photoelectric Smoke Detector FASD1

Modern protection for home and business

Attention! The device works autonomously, does not require the Smart Hub FS2SH gateway to operate and is not available in the Ferguson Home application.

In an era of increasing fire safety requirements, a modern photoelectric smoke detector is becoming an essential element of a security system, both in homes and in public and industrial facilities. Thanks to groundbreaking smoke detection technology, our detector provides a rapid response to any threat, minimizing the risk of property damage, loss of health, or even death. By investing in this innovative product, you can be sure that your family, employees, and customers are adequately protected in any fire-related situation.

Description

Photoelectric Smoke Detector FASD1

Fotoelektryczny czujnik dymu FASD1

Why choose the FASD1 photoelectric smoke detector?

  1. Modern detection technology

The FASD1 photoelectric smoke detector uses advanced optical detection technology to detect smoldering fires at a very early stage—before they develop into a full-blown blaze. It works by analyzing changes in light intensity within the detection chamber, making it particularly effective against smoke-based fires (e.g., furniture, electrical, or paper wall fires). This allows the device to provide valuable time to initiate an evacuation and call emergency services.

  1. Intelligent functions for comfort and safety

The sensor is equipped with a number of amenities:

  • Operational Testing – A dedicated button allows users to regularly check the sensor’s operation. Testing not only ensures the device is working properly but also raises awareness among household members about the importance of maintaining a functioning alarm system.
  • Low battery notifications – The built-in system warns with a visual signal (red LED) when the battery level is low, allowing you to replace the battery before the device stops working.
  • Alarm Pause (Hush Mode) – In situations where the alarm sounds without a real threat (e.g., cooking or dust), you can temporarily silence the alarm. This feature is extremely useful for minimizing false alarms, but in critical situations, the sensor will automatically resume operation within 10 minutes.
  • Visible and audible alarm signals – The device generates a strong audible signal and a flashing green or red LED, ensuring that everyone, regardless of their location in the building, will hear and see the alarm when a threat is detected.
  1. Easy installation and minimal service requirements

Installing the FASD1 smoke detector is simple and intuitive. Thanks to its universal mounting system (wall or ceiling) and the included mounting kit (a mounting bracket and wall plugs are included), the device can be installed without the need for specialist services – although we recommend contacting a qualified electrician to ensure proper installation. The step-by-step instruction manual details installation locations (e.g., avoiding “dead space” at ceiling peaks) and provides advice on optimal device placement within the building. Regular cleaning and testing (e.g., once a month) ensures long-term and reliable operation of the detector.

Examples of use in various facilities

Apartment or family home

In a typical single-family home, the FASD1 smoke detector is recommended for installation in hallways, near bedrooms, and in living rooms. Thanks to its central location, every household member—regardless of whether they’re in another part of the home or even asleep—will be immediately alerted to a threat. In everyday situations, such as cooking or smoking, the intelligent alarm pause function helps avoid unnecessary nuisance without compromising safety.

Public and commercial facilities

In offices, hotels, preschools, and hospitals, where the safety of many people is a priority, the FASD1 photoelectric smoke detector guarantees rapid threat detection, enabling efficient evacuation. The alarm system, located in key corridors and at room entrances, ensures that every employee, visitor, and child hears the warning signal. In large facilities, where sensor placement can be strategically varied, the device is ideal as an integral component of a comprehensive fire detection system.

Industry and production halls

In industrial facilities where specific hazards related to production processes (e.g., exhaust fumes, dust, or chemicals) may occur, the FASD1 photoelectric smoke detector provides robust protection. Its ability to detect small amounts of smoke translates into the ability to take immediate emergency action, minimizing potential losses and the risk of accidents. Even in harsh environmental conditions, the device maintains high efficiency thanks to its resistance to external factors, making it an ideal choice for industrial plants and warehouses.

Why is safety essential?

The safety of your family, employees, and property shouldn’t be left to chance. The FASD1 photoelectric smoke detector is not only a modern device, but above all, an investment in peace of mind and the assurance that you’ll be properly warned in the event of a fire. For example, if a small but smoldering fire begins to develop in the kitchen—perhaps as a result of overheated grease or improperly operated household appliances—the detector will immediately detect the presence of smoke and sound the alarm. This means that even if the alarm is partially suppressed by daily activities, everyone in the household (even while sleeping) will hear the warning signal, giving you time to evacuate and call the fire department.

In public facilities such as hotels and schools, minimizing risk and responding quickly to threats is crucial. Regular testing and maintenance ensure the alarm system operates under all conditions, contributing to the safety of all facility users.

In industrial environments where dust, fumes, or other atmospheric factors can impact the performance of traditional sensors, the FASD1 photoelectric smoke detector is designed to withstand external factors. Its reliable threat detection helps minimize production downtime and avoid potential financial losses resulting from fire.

Notes on installation and use

Mounting Location: To ensure maximum effectiveness, the FASD1 smoke alarm should be mounted in central areas of rooms, away from drafts, windows, ventilation doors, and directly above sources of steam (kitchen, bathroom). Installation in corridors connecting main areas of the building, such as bedrooms and living rooms, is also recommended.

False alarm prevention: The device features a “pause alarm” (Hush Mode) that allows you to temporarily silence the alarm in the event of a false alarm, such as during intense cooking. However, please note that this feature is only for non-critical situations; in the event of a real emergency, the alarm will resume automatically.

Education and training: To effectively utilize the potential of your alarm system, it’s important to regularly conduct evacuation drills at home, in the office, or at school. This will ensure that every household member or employee knows what to do in an emergency, significantly increasing the chances of safely escaping the building in the event of a fire.

Summary

The FASD1 photoelectric smoke detector combines advanced technology, reliability, and intuitive operation. Its numerous features—from automatic testing and an intelligent LED marking system to a convenient alarm pause function—make it an excellent solution for both single-family homes and commercial and industrial facilities. Compliance with international standards (CE, CPR, DOP) and high-quality construction ensure the FASD1 smoke detector meets the highest fire safety standards. Regular maintenance, easy installation, and clear instructions guarantee that the device will effectively protect you, your loved ones, and your property for many years to come.

If you’re looking for a reliable solution that offers rapid threat detection, minimizes false alarms, and ensures the constant safety of your surroundings, the FASD1 photoelectric smoke detector is the product for you. By investing in this alarm system, you’re investing in safety, peace of mind, and a future that always puts people first.

Technical Specifications

  • Detection technology: Photoelectric (based on optical detection of contaminants in the chamber)
  • Operating voltage: 3V (powered by a single CR123A or CR17335 battery – non-replaceable)
  • Operating time/battery: Up to 10 years of continuous operation – no need to replace the battery throughout its lifespan
  • Alarm signal: An audible signal of approximately 85 dBA (measured at 3 meters from the sensor) provides an immediate warning
  • Visual signal: LED – in normal operation mode, it lights up approximately every 53 seconds; in the event of an alarm, the signaling changes (rapid flashing of red LEDs)
  • Operating conditions: Temperature: 0°C to +55°C; Humidity: 35–60% (non-condensing)
  • Dimensions: Φ60 mm x H34.5 mm
  • Installation: Can be mounted on the ceiling or wall – professional mounting kit included (bracket, wall plugs and installation instructions)
  • Standards and certificates:
    • CE mark – confirmation of compliance with European Union standards
    • CPR Certificate – meeting stringent requirements related to the safety of fire protection devices
    • DOP
    • Other industry standards for alarm systems
    • Compliance with ROHS/REACH standards (regarding materials used in production)
  • Additional functions
    • Push-button test – allows for periodic device checks
    • Automatic switch from alarm mode to normal mode after 10 minutes if the alarm pause function is activated
    • Low battery indicator – LED signal and sound notification that the battery needs to be replaced
  • Service Life and Maintenance: Regular cleaning (e.g., once a month using a soft brush) and periodic testing (weekly recommended) ensure long-lasting, reliable operation. The device should be replaced after 10 years of use or if any abnormalities are observed.
Go to Top